Procurement Glossary
Gage R&R: Measurement system analysis for reliable quality assessment
November 19, 2025
Gage R&R (Repeatability and Reproducibility) is a statistical method for evaluating the measurement accuracy and reliability of test equipment in quality assurance. This analysis enables buyers to assess the reliability of supplier measurements and make informed decisions about quality standards. Learn below what Gage R&R is, how the analysis process works, and what strategic advantages it offers for procurement management.
Key Facts
- Gage R&R measures the repeatability and reproducibility of measurement systems.
- Acceptable R&R values are typically below 10% of the tolerance for critical measurements.
- The method identifies measurement errors caused by variations in inspectors, equipment, and interactions.
- Standardized implementation is carried out in accordance with AIAG MSA-4 guidelines with at least 10 parts and 2-3 inspectors.
- Results directly influence supplier ratings and quality agreements
Contents
What is Gage R&R? Definition of the measurement system analysis process
Gage R&R is a fundamental method of measurement system analysis that quantifies the reliability of test equipment and identifies measurement uncertainties.
Basic components of the gauge R&R analysis
The analysis is divided into two main components: Repeatability describes the variation in repeated measurements of the same part by the same tester under identical conditions. Reproducibility captures the variation between different testers when measuring the same part.
- Repeatability (equipment variation): Measurement deviations caused by equipment
- Reproducibility (appraiser variation): Differences due to the appraiser
- Interaction: Interactions between the tester and the object being measured
Gage R&R versus other measurement methods
Unlike simple calibrations, Gage R&R evaluates the overall variability of the measurement system. While process capability analyses evaluate product quality, Gage R&R focuses on the measurement quality itself.
Significance of Gage R&R in Procurement
For procurement managers, Gage R&R enables the objective evaluation of supplier measurement systems and the establishment of reliable quality agreements. The method supports supplier selection and reduces quality-related risks through validated measurement processes.
Process steps and responsibilities
The systematic implementation of a Gage R&R study follows standardized procedures and requires a clear division of roles between Procurement, quality assurance, and suppliers.
Preparation and study design
Planning begins with the selection of representative measurement objects that cover the entire tolerance range. At least 10 parts are measured three times each by 2-3 trained inspectors. Measurement system analysis requires calibrated test equipment and standardized measurement conditions.
Data collection and statistical analysis
Measurements are taken in random order to avoid systematic errors. Statistical software calculates variance components and %R&R values. Results below 10% are considered acceptable, values between 10-30% are considered conditionally acceptable.
- Data collection in a structured matrix
- ANOVA-based variance analysis
- Calculation of %R&R and discrimination ratio
Implementation of improvement measures
If the results are unsatisfactory, targeted measures are initiated: examiner training in cases of high reproducibility, equipment maintenance in cases of high repeatability. Lessons learned are incorporated into future studies and continuously improve measurement quality.

Tacto Intelligence
Combines deep procurement knowledge with the most powerful AI agents for strong Procurement.
Key KPIs and targets for Gage R&R
Specific key figures enable objective evaluation of measurement system performance and support data-based decisions in quality management.
Primary fee R&R key figures
The %R&R value is the key indicator and should be below 10% of the tolerance for critical measurements. The discrimination ratio (ndc) indicates how many distinguishable categories the measurement system can recognize—values ≥5 are required.
- %R&R < 10%: Messsystem akzeptabel
- %R&R 10-30%: Conditionally acceptable, improvements required
- %R&R > 30%: Measurement system unsuitable
- ndc ≥ 5: Sufficient discriminatory power
variance component analysis
The division of the total variance into repeatability, reproducibility, and part-to-part variation identifies potential for improvement. High repeatability indicates equipment problems, while high reproducibility indicates examiner problems. Process capability indices are influenced by measurement system variability.
Operational performance indicators
Measurement system availability and calibration interval compliance are important secondary metrics. The number of successful Gage R&R studies per quarter indicates the quality maturity of the organization. Quality gates integrate Gage R&R results into approval processes.
Risks, dependencies and countermeasures
Gage R&R studies carry specific risks that, if conducted improperly, can lead to erroneous conclusions and costly quality problems.
Methodological risks and study design errors
An unrepresentative partial selection distorts results and leads to incorrect measurement system assessments. Sample sizes that are too small significantly reduce statistical significance. Untrained inspectors or inconsistent measurement conditions impair the validity of the analysis.
- Systematic selection of reference parts across the entire tolerance range
- Use at least 10 parts and 2-3 qualified inspectors.
- Ensure standardized measurement procedures and environmental conditions
Interpretation and application risks
Misinterpretation of %R&R values can lead to unnecessary investments or overlooked quality risks. Isolated consideration without taking process variability into account distorts the overall assessment. Quality costs increase due to inadequate measurement system evaluation.
Supplier and communication risks
Insufficient coordination with suppliers regarding fee R&R requirements leads to conflicts in complaint assessments. Lack of documentation makes traceability and auditability difficult. Regular training and clear quality assurance agreements minimize these risks.
Practical example
An automotive supplier conducts a Gage R&R study for measuring the thickness of critical seals. Three inspectors measure 10 parts three times each using a digital caliper. The evaluation yields a %R&R value of 15%, with 80% of the variation attributable to reproducibility. This indicates inspector-related differences.
- Identification of the main source of variation: examiner influence dominates
- Conducting targeted examiner training courses on measurement technology
- Repeat of the study after training: %R&R reduced to 8%
- Integration of results into supplier evaluation and quality agreement
Trends and developments related to Gage R&R
Modern technologies and digital transformation are fundamentally changing the way Gage R&R studies are conducted and evaluated, opening up new possibilities for quality assurance.
Digitization and automated measurement systems
Automated measuring stations significantly reduce examiner-related variations and enable continuous gauge R&R monitoring. Digital measurement data acquisition eliminates transmission errors and speeds up statistical evaluations. Statistical process control integrates gauge R&R results into real-time quality monitoring.
AI-supported measurement system optimization
Artificial intelligence analyzes complex measurement data patterns and identifies subtle factors influencing measurement system variability. Machine learning algorithms predict measurement system drift and optimize calibration intervals. Predictive analytics enables proactive maintenance strategies for critical test equipment.
Integration into digital quality management systems
Cloud-based platforms connect Gage R&R data with quality management systems and enable cross-location comparisons. Blockchain technology ensures data integrity and traceability of measurement results. Mobile apps support decentralized data collection and real-time evaluation.
Conclusion
Gage R&R is an indispensable tool for evaluating measurement system reliability and forms the basis for informed quality decisions in Procurement. The systematic application of this method enables objective supplier evaluations and significantly reduces quality-related risks. Modern digital technologies and AI integration open up new opportunities for continuous measurement system optimization. Successful implementation requires methodological expertise, clear processes, and consistent application throughout the supply chain.
FAQ
What does a %R&R value of 25% mean in practice?
An R&R value of 25% means that 25% of the observed variation is attributable to the measurement system. This is considered conditionally acceptable and requires improvement measures. The measurement system can still be used, but should be optimized to increase measurement accuracy.
How often should Gage R&R studies be repeated?
Gage R&R studies should be performed annually or after significant changes to the measurement system. For critical measurements, a semi-annual review is recommended. After repairs, calibrations, or tester changes, revalidation is required.
What role does Gage R&R play in supplier evaluation?
Gage R&R results flow directly into the evaluation of supplier measurement systems and influence quality agreements. Suppliers with proven, reliable measurement systems receive higher ratings and may be given preferential treatment. Inadequate measurement system capability can lead to retraining or a change of supplier.
What are typical causes of poor Gage R&R results?
Common causes include inadequate tester training, defective or worn measuring devices, unsuitable measuring methods, or unstable environmental conditions. Tolerances that are too narrow in relation to the measurement resolution can also cause problematic results. A systematic root cause analysis identifies the main influencing factors.



.avif)
.png)
.png)


.png)